SENSORS
PRESSURE
Piezoresistive transducer
Range: 0 … 1 bar, relative (other ranges on request)
Linearity / precision: max. ±0.02% of full scale
Total error band: max. ±0.1% of full scale
TEMPERATURE
Range: -40 ... +125 °C
Accuracy: max. ±0.1 °C
APPLICATIONS
- Level / depth in tanks for liquids
- Boreholes
- Groundwater and wells
- Running or open water level and quality
- Salinity and chloride monitoring
DEVICE
- LoRaWAN™ class A
- 2 C alkaline batteries
- 13.5 cm × 8.1 cm × 7 cm (not including sensor / cable)
- 10 m cable
Reference DL-PR36CDT Datasheet
For questions and/or volume pricing for 10 or more units, please send us a request: [email protected]